LED alarm event reporting (1byte) |
Parameter: 2 LED alarm event reporting (1 byte) Options: 0: Off 1: On Default: 1 Description: Turn On or Off Alarm event LED feedback. |
Parameter: 3 Temperature & Light reporting frequency (1 byte) Options: 1: Normal 2: Frequent Default: 1 Description: Normal: When temperature has changed more than 1°C since last report & more than 1 hour have passed and When 24 hours have passed since the last report was sent. Slow response to Light change. Frequent: When temperature has changed more than 0.5°C since last report & more than 15 minutes have passed and When 6 hours have passed since the last report was sent. Fast response to Light change. |
|
Parameter: 4 Temperature reporting (1 byte) (Does not affect temperature alarms) Options: 0: Off 1: On Default: 1 Description: Turn On or Off reporting of the Temperature. |
|
Parameter: 5 Temperature reporting unit (1 byte) Options: 0: Celsius 1: Fahrenheit Default: 0 Description: Receive Temperature reports in the format you are comfortable with, i.e. Celsius vs Fahrenheit. |
|
Parameter: 6 Temperature alarms (1 byte) Options: 0: Off 1: On Default: 0 Description: Generic setting to Turn On or Off the Temperature Alarm. |
|
Parameter: 7 High temperature alarm level (1 byte) Options: -20 to +60 (degree C) Default: 60 Description:
|
|
Parameter: 8 Low temperature alarm level (1 byte) Options: -20 to +60 (degree C) Default: -20 Description: Temperature Alarm
|
|
Parameter: 9 Ambient light reporting (1 byte) Options: 0: Off 1: On 2: Report only when levels defined in parameter 10 & 11 are passed. Default: 1 Description: Turn On or Off Lux reporting or #2 – Only filter for certain Lux levels (See Config Parameters 10 & 11) |
|
Parameter: 10 High ambient light report level (4 bytes) Options: 3 - 64000 Default: 40000 Description: Send Lux Report when detected light above the set High Ambient light level. |
|
Parameter: 11 Low ambient light report level (4 bytes) (Must be significantly lower than parameter 10) Options: 1 - 42000 Default: 5000 Description: Send Lux Report when detected light below the set Lux Ambient light level. |
|
Parameter: 12 Leakage alarm (1 byte) *Strips Comfort pre-set to 0 Options: 0: Off 1: On Default: 1* Description: Setting to turn On or Off the Leakage Alarm and it follows the level set in configuration parameter no. 13. |
|
Parameter: 14 Moisture reporting period (1 byte) Options: 0-120 (Hours between reports) Default: 0 (Off) Description: Based on the duration set, Strips MS periodically reports the moisture level. |